Burglar Alarms
Burglar Alarm Surge Suppression
1PRJ11: If your power side of the system is connected by plug-into 110-volt AC, this unit has one outlet and should be installed in front of the plug-in transformer.
D Dual 2W 15V: 15 Volts DC to be used on the Contact/Sensor loops or dedicated (non-ring type) modem lines.
DLT 1P 200: Installation: Connect the red and green leads to terminal 4 and 5. Install the unit as close to the RJ31X Telco Block as possible and keep the leads from the DLT 1P as short as possible. Run the ground wire to the nearest AC unified earth ground.
T12MD: 12 Volts DC to be used on the initiating circuits, addressable loops, and NAC loops operating at 12Volts DC drawing less than 5 amps. These 2 pair / 4 wire surge protection devices have screw terminals (4 in and 4 out)
T12MDP: 12 Volts DC to be used on the initiating circuits and addressable loops operating at 12Volts DC drawing less than 150 milliamps. These 2 pair / 4 wire surge protection devices have screw terminals (4 in and 4 out)
T120MDP: 130Volts RMS to be used on equipment connected to your telecommunication lines with ring voltage. i.e.(RJ31X) alarm dialers etc. This 2 pair / 4 wire surge protection device has removable screw terminals (4 in and 4 out) for ease of installation and or replacement.
RJ31120MDP: 130Volts RMS to be used on equipment connected to your telecommunication lines with ring voltage with RJ31X connection. This device has Female RJ31X connectors (1 in and 1 out).
|
|