CCTV
E-Clips Surge Suppression products for Camera Systems:
CCTV BNC V or CCTV BNC C/V Are Hybrid in-line series coaxial units and should be installed at the camera and head end equipment. No external ground is necessary because these units dissipate within themselves. Passes both video and data.
CATV 24 VAC or CATV 12 VDC Is a 24-volt AC parallel hardwire unit (or 12-volt VDC). The hardwire leads should go under screws on the camera for the 24-volt power source. A ground lug is provided and should only be used if you have a 3-wire application (phase, neutral, ground). If just using phase and neutral, you should not use the ground lug. This unit is not amperage sensitive.
DDUAL2W60NC Is a 24-volt AC screw terminal 3 Stage Hybrid in-line series hardwire unit for camera power applications and does NOT require grounding.
DDUAL2W30BH Is a 24-volt DC screw terminal series hardwire unit used for 24-volt DC camera power applications. DDUAL2W15BH is used for 12-volt DC fiber transmit/receive power protection and or 12-volt DC camera power.
1PRJ11: Is a 110-volt single outlet AC plug-in device for 15amp applications.
1208CS Are 110-volt AC 8 outlet plug-in power strip protector for the step down transformers, monitors, recorders, multi-plexers, switchers, amplifiers etc.
D Dual 4W 6.8 or D Dual 2W 6.8 Are 3 Stage Hybrid in-line series screw terminal multi-stage hybrid devices for the four wire (4W) or two wire (2W) data loop, pan/tilt (RS422) or twisted pair video. These units pass both video and data. These should be installed at the camera, receiver driver, controller and or head end equipment. There is a ground lug provided. Only use if you have a common ground i.e. single ground for entire system to prevent ground loops. (D Dual 6W 6.8 also available for 6wire/3pair applications)
D Dual 2W 60/FA60 Are 3 Stage Hybrid in-line series screw terminal multi-stage hybrid device for 24-volt AC power to cameras without heater blowers. This unit should be used for applications drawing 1 amp or less. A ground lug is provided and should only be used if you have a 3-wire application (phase, neutral, ground). If just using phase and neutral, you should not use the ground lug. Use the DDUAL2W60NC/FA60NC if more than 1amp/heater blower, fan, PTZ power etc.
CCTV BNC V 32 Is a19” Rack mount 32 BNC (Female In/Female Out), 2U rack space coaxial Hybrid in-line series surge suppressor with In-Field Replaceable Modules for your DVR, multi-plexer or other head end equipment. Can also stand alone. Does not require grounding.
D DUAL 32 W 6.8- 19” Rack mount 64 Screw Terminal (32 In/ 32 Out), 2 rack space, hardwire Hybrid in-line Series surge suppressor with In-Field Replaceable Modules for controller head end equipment.
VLPRJ45: In line-series protection for camera over IP Ethernet with RJ45 Jack & Plug connections.
Grounding issues are very important. Should you have any questions or require assistance with the installation, please call Jan Butler @ 727-525-5552 or 800-526-1556 Ext. 208 for technical assistance, pricing or additional information.
|
|